Our Projects

Our Projects

Automating the Temperature Control Procedure of Paper Machine Bearing Units

Temperature Control System (TCS) enables real-time temperature measurement of bearing unit surfaces.

Features:

  • Data collection and analysis system.
  • Alarm system.
  • Visualization system.

Purpose: Monitoring the temperature of bearing unit surfaces.

Description: The Temperature Control System (TCS) provides real-time temperature measurement of bearing unit surfaces. The TCS displays information on the operator’s monitor, indicating the temperatures of the bearing unit surfaces. The operator can set maximum values for each sensor using the control panel (touchscreen monitor). The TCS allows archiving data for a period of up to 12 months, displaying temperature graphs, and storing essential information. Additionally, it supports up to 300 temperature control points.

Technical Specifications:
Data Collection System:

Measurement temperature range: +50…250 ℃.
Ambient temperature range: -20…+130 ℃.
Humidity range: 50 – 100%.
Alarm System:

Ambient temperature range: -20…+70 ℃.
Humidity range: 50 – 80%.
Visualization System:

Ambient temperature range: -5…+60 ℃.
Humidity range: 50 – 70%.
Environmental Conditions:

Operating temperature: Up to +100 ℃.
Humidity: Up to 95%.